PMF_darcylaw_kdarcy(): Hydraulic conductivity

About:
Calculate the hydraulic conductivity of a soil, based on the intrinsic conductivity in a porous media.
\begin{equation} K = \frac{k \times \gamma}{\mu} \end{equation}

Where,



  • $K$, hydraulic conductivity - $\frac{m}{s}$;
  • $k$, intrinsic permeability - $m^2$;
  • $\gamma$, fluid specific weight » WATER_density_gamma(), $\frac{N}{m^3}$;
  • $\mu$, dynamic viscosity » WATER_viscosity_dvisc(), $Pa \times s$.

  • Module: PorousMediaFlow
    Function: PMF_darcylaw_kdarcy(t,s,k)
    Parameters:
    • t , water temperature, oC;
    • s, water salinity, g/kg;
    • k, intrinsic permeability, m2.
    Sample code:
    from PorousMediaFlow import *
    
    t = 10 #(.oC)
    s = 2.5 #(g/kg)
    k = 10**(-10) #(m2)
    
    kdarcy = PMF_darcylaw_kdarcy(t,s,k)
    
    print("K:",kdarcy,"m/s")
    
    Result:
    K: 0.0007559003751319023 m/s